Home > Product Show

YLN-D08

YLN-D08 Radar Water Level Gauge

This product is not affected by environmental factors such as temperature, humidity, air pressure, rain, snow, wind and sand, thus then radar water level gauge is quite stable, with very high accuracy within its working range and no need for maintenan…

Order Online
  • Product Principle
  • Product Features
  • Technical Parameters

This product is not affected by environmental factors such as temperature, humidity, air pressure, rain, snow, wind and sand, thus then radar water level gauge is quite stable, with very high accuracy within its working range and no need for maintenance. It is applied to river water level, automatic monitoring of open channel water level, tail water level monitoring in front of and under the reservoir dams, surge tower (well) water level monitoring, automatic tide level monitoring system, urban water supply, and sewage level monitoring system.

This product is not affected by environmental factors such as temperature, humidity, air pressure, rain, snow, wind and sand, thus then radar water level gauge is quite stable, with very high accuracy within its working range and no need for maintenance. It is applied to river water level, automatic monitoring of open channel water level, tail water level monitoring in front of and under the reservoir dams, surge tower (well) water level monitoring, automatic tide level monitoring system, urban water supply, and sewage level monitoring system.

Power supply voltage

Four-wire system

624) V DC / RS485  Modbus  /power consumption  90mW

Two-wire system

DC 24V / 4~20mA / power consumption   0.75W

Allowed ripple

- <100Hz            Uss<lV 

 - (100~100K) Hz     Uss<l0mV

Cable parameters

Cable inlet/plug

 M20xl.5 cable inlet

Terminals

 Cable section1.0mm²

Output parameters

Output signal

RS485 Modbus / 4~20mA

Protocol

Modbus / Hart

Resolution

 1. 6μA

Fault signal

Current output does not change.

20. 5mA

22mA

3.9mA

Integration time

 (036)s,adjustable

Blind spot

Antenna end

Max. measuring distance 

Small range

30m

Large range

70m

Microwave frequency

26GHz

Measurement interval

About 1s(depending on parameter setting

Adjustment time

About 1s(depending on parameter setting

Display resolution    

1mm

Working storage and transportation temperature

 (-4070) 

Process temperature (temperature of the antenna part)

 (-40100)

Pressure

Normal pressure

Shockproof

Mechanical vibration l0m/s², (10~150)Hz