Home > Product Show

YLN-YGS60

YLN-YGS60 Laser Water Level Gauge

This product is a new type of non-contact measuring instrument. It adopts the principle of laser ranging which is superior to its kind. The imported inner core guarantees the long-term stability of measurement accuracy. It can be fixed directly on the…

Order Online
  • Product Principle
  • Product Features
  • Technical Parameters

This product is a new type of non-contact measuring instrument. It adopts the principle of laser ranging which is superior to its kind. The imported inner core guarantees the long-term stability of measurement accuracy. It can be fixed directly on the top of the gate, no need protective pipe. During measurement, the instrument emits a red laser beam to the surface of the object to be measured, and then measures the value and outputs it through EIA-485 interface. When measuring the water level, it only needs to install a laser beam protection pipe vertically or obliquely, which solves the difficulty of constructing a standard shaft and the problems of expenses.

This product is a new type of non-contact measuring instrument. It adopts the principle of laser ranging which is superior to its kind. The imported inner core guarantees the long-term stability of measurement accuracy. It can be fixed directly on the top of the gate, no need protective pipe. During measurement, the instrument emits a red laser beam to the surface of the object to be measured, and then measures the value and outputs it through EIA-485 interface. When measuring the water level, it only needs to install a laser beam protection pipe vertically or obliquely, which solves the difficulty of constructing a standard shaft and the problems of expenses.

Name

Technical Parameters

Measurement distance

0.2~100m

Laser type

635nm Class II safety, laser spot: 1mm wide and 3mm long, beam angle: <0.05°

Measurement accuracy

Full range ±1mm, output resolution 1mm, 1cm settable

Measurement frequency

Fast measurement speed, return to normal data in 8 seconds

Communication Interface

Standard 232 or 485 interface, MODBUS protocol

Address range

1~254

Operation Voltage

DC6~26V wide voltage, 50mA, external battery

On-duty power consumption

485 on duty, less than 2mA when not measuring, not displaying

Sampling interval

1 minute to 24 hours settable

Storage capacity

16MB memory, water level storage, power down storage

Working environment

Work: -20~+60℃; Storage: -30~+70℃; Humidity: 95%RH

Dimensions