YFe-2361

YFe-2361 Automatic Online Monitor of Iron in Water

Inject the sample into the reaction pool by a syringe pump, add in the acidic reagent, and then heat the mixed sample to 95C to dissolve the suspended iron; secondly, inject the buffer, adjust to a proper pH value for reduction, and reduce the ferric …

Order Online
  • Product Principle
  • Product Features
  • Technical Parameters

Inject the sample into the reaction pool by a syringe pump, add in the acidic reagent, and then heat the mixed sample to 95°C to dissolve the suspended iron; secondly, inject the buffer, adjust to a proper pH value for reduction, and reduce the ferric iron to divalent; finally, the chromogenic agent, iron ions and the chromogenic agent are added to generate a purple complex, and then the absorbance of the complex is measured at the specified wavelength with a colorimeter to calculate the total iron content.

Characteristics:

Valve components selection. It can select the reagent sampling sequence, with flexible channels, variable functions, minimum dead volume, easy maintenance, long service life and other advantages.

Printing function. It can be connected to a printer (optional order) to print the measured data in time.

It adopts 7-inch touch screen, with simple operation interface, easy for users to learn, operate, and maintain.

Super large data storage capacity. It can realize storage of historical data for no less than 5 years (measurement interval is 1 time/1h), which greatly meets the needs of customers.

Automatic leakage alarm function. When reagent leakage occurs, the instrument will automatically alarm to remind the user to perform maintenance.

Light signal recognition function to ensure high accuracy of quantification.

Simple and convenient chemical reagents maintenance. The reagents can be replaced once a month, which greatly reduces the maintenance of the user.

U disk one-click upgrade. The software update is much easier.

1 Method basis: spectrophotometry.

2 Measuring range: 0.01~10.0mg/L.

3 Accuracy: ±10% or ±0.1mg/L (the larger of the two).

4 Repeatability: 10% or 0.1mg/L.

5 Measurement period: The minimum measurement period is 30 minutes.

6 Sampling cycle: time interval (10~9999min arbitrarily adjustable) and hourly measurement mode.

7 Calibration cycle: It can be calibrated manually immediately or set cycle for automatic calibration.

8 Maintenance cycle: generally, once a month, each time is about 30 minutes.

9 Output: RS-232.

10 Environment requirements: temperature +5~30℃; humidity ≤90%RH (no condensation).

11 Power supply: AC (220±10%) V, (50±10%) Hz, 5A.