YLN-CODmn-2002 Automatic Online Monitor of Permanganate Index

Add a known amount of potassium permanganate and sulfuric acid to the sample, and heat it for a certain time under high temperature. Potassium permanganate oxidizes some organic and inorganic reducing substances in the sample. After the reaction, add …

Order Online
  • Product Principle
  • Product Features
  • Technical Parameters

Add a known amount of potassium permanganate and sulfuric acid to the sample, and heat it for a certain time under high temperature. Potassium permanganate oxidizes some organic and inorganic reducing substances in the sample. After the reaction, add excess sodium oxalate to reduce the remaining Potassium permanganate, use potassium permanganate standard solution to titrate back to excess sodium oxalate, and calculate the permanganate index in the sample.

Characteristics:

Valve components selection. It can select the reagent sampling sequence, with flexible channels, variable functions, minimum dead volume, easy maintenance, long service life and other advantages.

Printing function. It can be connected to a printer (optional order) to print the measured data in time.

It adopts 7-inch touch screen, with simple operation interface, easy for users to learn, operate, and maintain.

Super large data storage capacity. It can realize storage of historical data for no less than 5 years (measurement interval is 1 time/1h), which greatly meets the needs of customers.

Automatic leakage alarm function. When reagent leakage occurs, the instrument will automatically alarm to remind the user to perform maintenance.

Light signal recognition function to ensure high accuracy of quantification.

Simple and convenient chemical reagents maintenance. The reagents can be replaced once a month, which greatly reduces the maintenance of the user.

U disk one-click upgrade. The software update is much easier.

1 Method basis: spectrophotometric detection.

2 Measuring range: 0-50 mg/L.

3 Accuracy: no more than ±5% or no more than ±0.02mg/L.

4 Repeatability: no more than ±5% or no more than ±0.02mg/L.

5 Measurement period: The minimum measurement period is 20 minutes. According to the on-site environment, the color development time can be arbitrarily modified within 5 to 120 minutes.

6 Sampling cycle: time interval (10~9999min arbitrarily adjustable) and hourly measurement mode.

7 Calibration cycle: adjustable at any interval from 1 to 99 days.

8 Maintenance cycle: 1 time/month.

9 Reagent consumption: less than 0.1 RMB/sample.

10 Display: 10-inch color screen, 1024*600, 16.77 million true colors. .

11 Output: RS-232, 4-20mA (optional).

12 Communication protocol: Modbus RTU, new national standard protocol, dynamic control protocol, and others.

13 Environment requirements: indoor with adjustable temperature, recommended temperature +5~28℃; humidity ≤90% (no condensation).

14 Power supply: AC220±10% V, 50±10% Hz, 5A.