Home > Product Show

YLN-RDA1D

YLN-RDA1D Radar Flowmeter

The product can continuously measure the water flow of rivers and open channels, and obtain the surface velocity and water level by non-contact measurement. For regular channel section, it uses the conventional mathematical formulas to calculate the f…

Order Online
  • Product Principle
  • Product Features
  • Technical Parameters

The product can continuously measure the water flow of rivers and open channels, and obtain the surface velocity and water level by non-contact measurement. For regular channel section, it uses the conventional mathematical formulas to calculate the flow results. For irregular river section, the flow rate is calculated by tracing point method and calculus calculation. Non-contact measurement method will not be affected by sediment, weeds or other debris, with reduced maintenance costs and increased reliability.

The product can continuously measure the water flow of rivers and open channels, and obtain the surface velocity and water level by non-contact measurement. For regular channel section, it uses the conventional mathematical formulas to calculate the flow results. For irregular river section, the flow rate is calculated by tracing point method and calculus calculation. Non-contact measurement method will not be affected by sediment, weeds or other debris, with reduced maintenance costs and increased reliability.

Flow rate measurement range

0.1m/s~20m/s (related to water flow regime)

Flow rate measurement accuracy

±0.01m/s;±1%FS

Flowmeter frequency

24GHz

Flowmeter beam angle

12°

Ranging range

0~45m

Ranging accuracy

±2mm

Frequency of water level gauge

24-26GHz

Beam angle of water level gauge

10°

Water level antenna

Planar micro-strip array antenna

Intelligent sensing and compensation of attitude angle

Horizontal angle, roll angle accuracy ±0.5°; resolution ±0.1°

Data interface

RS-485,MODBUS Protocol

Baud rate

9600-115200bps

Work voltage

DC6~30V,recommended 12V

Power consumption

Work current<80mA, stand-by current55mA(@DC12V)

Work temperature

-40~+80

Protection level

IP68

Product dimension

313x140x271mm length x width x height